Rockwell Automation 1756-DMF30 ControlLogix Drive Module User Manual

Page 105

Advertising
background image

Publication 1756-UM522B-EN-P - February 2003

1756-DMD30 Specific Information B-25

17

Jog Speed 1

Provides the speed reference that the drive uses when
responding to bit 18 [Jog 1] of parameter 152 [Applied
LogicCmd].

Units:
Default:
Min:
Max:
Type:
File:
Group:

RPM
0
-14000
14000
Linkable, Read-Write, Floating Point
Speed Control
Reference

18

Jog Speed 2

Provides the speed reference that the drive uses when
responding to bit 23 [Jog 2] of parameter 152 [Applied
LogicCmd].

Units:
Default:
Min:
Max:
Type:
File:
Group:

RPM
0
-14000
14000
Linkable, Read-Write, Floating Point
Speed Control
Reference

19

Atune Spd Ref

Sets the maximum speed of the motor during the Flux current
and inertia tests. A value of 1.0 represents base speed of the
motor.

Units:
Default:
Min:
Max:
Type:
File:
Group:

RPM
1487.5
525
1750
Non-Linkable, Read-Write, Floating Point
Speed Control
Regulator

21

Speed Trim 1

Provides an additive trim value to the Scaled Speed Reference.
A value of 1.0 represents base speed of the motor.

Units:
Default:
Min:
Max:
Type:
File:
Group:

RPM
0
-14000
14000
Linkable, Read-Write, Floating Point
Speed Control
Reference

22

Speed Trim 2

Provides an additive speed trim value with a Lead/Lag filter.
Position regulator output is linked to this parameter by default.
This speed trim value affects the speed reference input to the
speed regulator.

Units:
Default:
Min:
Max:
Type:
File:
Group:

RPM
0
-14000
14000
Linkable, Read-Write, Floating Point
Speed Control
Regulator

23

Speed Trim 3

Provides a scalable speed trim value that will be added to the
speed reference input to the speed regulator. Parameter 24
[SpdTrim3 Scale] scales this value prior to the trim value
affecting the speed reference. A value of 1.0 represents base
speed of the motor.

Units:
Default:
Min:
Max:
Type:
File:
Group:

RPM
0
-14000
14000
Linkable, Read-Write, Floating Point
Speed Control
Regulator

24

SpdTrim 3 Scale

This parameter is multiplied with the value in parameter 23
[Speed Trim 3].

Default:
Min:
Max:
Type:
File:
Group:

1
-3.2767
3.2767
Linkable, Read-Write, Floating Point
Speed Control
Regulator

No.

Name
Description

Values

Advertising
This manual is related to the following products: