Rockwell Automation 1756-DMF30 ControlLogix Drive Module User Manual
Page 251
Advertising

Publication 1756-UM522B-EN-P - February 2003
1756-DMD30 Specific Information B-171
9
F Par NotLod
Field configuration parameters have not been downloaded
into the PMI module from the Dive Module.
10
F Gns NotLod
Field configuration parameters have not been downloaded
into the PMI module from the Dive Module.
11
F Flt Rst Rq
Previous field faults (parameter 2122 [MC Faults]), e.g., field
loss and line synchronization loss faults, have not been
cleared.
14
F FB or CFG
A field current feedback fault or configuration error has
occured:
• The drive has sensed field current feedback when
the field is off.
• You have attempted to turn on the field without
setting parameter 2200 [PMI Drive Config] bit 12 [Fld
Reg Used].
Bit
Fault Name
Fault Description