B-82 1756-DMD30 Specific Information

602

Integer In01
Displays input word 01 of the controller communication format
in integer format. Paired with parameter 603 [Real In01],
which displays the same data in floating point format.

Default:
Min:
Max:
Type:
File:
Group:

0
-2147483648
2147483648
Non-Linkable, Read Only, 32-bit Integer
Communication
Logix Inputs

603

Real In01
Displays input word 01 of the controller communication format
in floating point format. Paired with parameter 602 [Integer
In01], which displays the same data in integer format.

Default:
Min:
Max:
Type:
File:
Group:

0
-2200000000
2200000000
Non-Linkable, Read Only, Floating Point
Communication
Logix Inputs

604

Integer In02
Displays input word 02 of the controller communication format
in integer format. Paired with parameter 605 [Real In02],
which displays the same data in floating point format.

Default:
Min:
Max:
Type:
File:
Group:

0
-2147483648
2147483648
Non-Linkable, Read Only, 32-bit Integer
Communication
Logix Inputs

605

Real In02
Displays input word 02 of the controller communication format
in floating point format. Paired with parameter 604 [Integer
In02], which displays the same data in integer format.

Default:
Min:
Max:
Type:
File:
Group:

0
-2200000000
2200000000
Non-Linkable, Read Only, Floating Point
Communication
Logix Inputs

606

Integer In03
Displays input word 03 of the controller communication format
in integer format. Paired with parameter 607 [Real In03],
which displays the same data in floating point format.

Default:
Min:
Max:
Type:
File:
Group:

0
-2147483648
2147483648
Non-Linkable, Read Only, 32-bit Integer
Communication
Logix Inputs

607

Real In03
Displays input word 03 of the controller communication format
in floating point format. Paired with parameter 606 [Integer
In03], which displays the same data in integer format.

Default:
Min:
Max:
Type:
File:
Group:

0
-2200000000
2200000000
Non-Linkable, Read Only, Floating Point
Communication
Logix Inputs

608

Integer In04
Displays input word 04 of the controller communication format
in integer format. Paired with parameter 609 [Real In04],
which displays the same data in floating point format.

Default:
Min:
Max:
Type:
File:
Group:

0
-2147483648
2147483648
Non-Linkable, Read Only, 32-bit Integer
Communication
Logix Inputs

609

Real In04
Displays input word 04 of the controller communication format
in floating point format. Paired with parameter 608 [Integer
In04], which displays the same data in integer format.

Default:
Min:
Max:
Type:
File:
Group:

0
-2200000000
2200000000
Non-Linkable, Read Only, Floating Point
Communication
Logix Inputs

No.

Name
Description

Values