Rockwell Automation 1756-DMF30 ControlLogix Drive Module User Manual

Page 141

Advertising
background image

Publication 1756-UM522B-EN-P - February 2003

1756-DMD30 Specific Information B-61

241

Anlg Tach Posit
Indicates accumulated position feedback generated by the
analog tach. This parameter supplies position regulator
feedback if postion control is enabled.

Default:
Min:
Max:
Type:
File:
Group:

0
-2147483648
2147483648
Non-Linkable, Read Only, 32-bit Integer
Speed/Posit Fdbk
Analog Tach

242

Arm Volts Spd FB
Displays speed feedback from armature voltage. Select
analog tach by entering a value of 6 in of parameter 222
[Motor Fdbk Sel]. Armature Voltage Feedback is calculated
using parameter 2137[Arm Volt FB Cnts] parameter 2151 [Arm
Resistance], and parameter 2127 [CML Feedback].

Units:
Default:
Min:
Max:
Type:
File:
Group:

RPM
0
-14000
14000
Non-Linkable, Read Only, Floating Point
Speed/Posit Fdbk
Armature Volts

243

Arm Volts Posit
Indicates accumulated position feedback generated by
armature voltage feedback. This parameter supplies position
regulator feedback if postion control is enabled.

Units:
Default:
Min:
Max:
Type:
File:
Group:


0
-2147483648
2147483648
Non-Linkable, Read Only, 32-bit Integer
Speed/Posit Fdbk
Armature Volts

300

Motor Spd Fdbk
Displays measured motor speed information from the selected
feedback device. A value of 1.0 represents base speed of the
motor.

Units:
Default:
Min:
Max:
Type:
File:
Group:

RPM
0
-14000
14000
Non-Linkable, Read Only, Floating Point
Monitor, Speed Control, Speed/Posit Fdbk
Metering, Regulator, Feedback Config

301

Motor Speed Ref
Displays the speed reference value, after the limit function.
This is the input to the error calculator and speed regulator. A
value of 1.0 represents base speed of the motor.

Units:
Default:
Min:
Max:
Type:
File:
Group:

RPM
0
-14000
14000
Non-Linkable, Read Only, Floating Point
Speed Control
Regulator

302

Spd Reg PI Out
Displays the output of the speed regulator. This is the input to
torque control. A value of 1.0 represents base Torque of the
motor.

Units:
Default:
Min:
Max:
Type:
File:
Group:

P.U.
0
-8
8
Non-Linkable
Read Only, Floating Point Speed Control,
Torque Control
Regulator, Torque

303

Motor Torque Ref
Displays the calculated value of motor torque. The actual
value of the motor torque is within 5% of this value.

Units:
Default:
Min:
Max:
Type:
File:
Group:

P.U.
0
-8
8
Non-Linkable, Read Only, Floating Point
Torque Control
Torque