Rockwell Automation 1756-DMF30 ControlLogix Drive Module User Manual

Page 225

Advertising
background image

Publication 1756-UM522B-EN-P - February 2003

1756-DMD30 Specific Information B-145

2130

Counter EMF
Displays the measured counter-EMF voltage, in volts.

Units:
Default:
Min:
Max:
Type:
File:
Group:

Volt
0
-32768
32767
Non-Linkable, Read Only, Floating Point
DPS/PMI
Feedback

2131

FML Feedback
Displays measured field current. A value of 4095 indicates hot
field current - equal to the value of parameter 2185 [Hot Field
Curr].

Units:
Default:
Min:
Max:
Type:
File:
Group:

P.U.
0
-4095
4095
Non-Linkable, Read Only, 16-bit Integer
Speed/Posit Fdbk
Resolver

2132

Field Amps Fdbk
Displays measured field current in Amps.

Units:
Default:
Min:
Max:
Type:
File:
Group:

Amps
0
-32768
32767
Non-Linkable, Read Only, Floating Point
DPS/PMI
Feedback

2133

Field Volt Fdbk
Displays the field voltage feedback value, in volts. This voltage
is calculated based on the AC line voltage and field firing
angle.

Units:
Default:
Min:
Max:
Type:
File:
Group:

Volt
0
-32768
32767
Non-Linkable, Read Only, Floating Point
DPS/PMI
Feedback

2134

User Anlg Input
Displays the measured user analog input value from the
Resolver Feedback connector on the Resolver & Drive l/O
module. This value may be accessed through the PMI meter
ports.

Default:
Min:
Max:
Type:
File:
Group:

0
-2048
2048
Non-Linkable, Read Only, 16-bit Integer
DPS/PMI
Feedback

2135

Res Scan Posit
Displays the electrical position of the resolver (if used). This
register is reset to zero at power-up.

Default:
Min:
Max:
Type:
File:
Group:

0
-32768
32767
Non-Linkable, Read Only, 16-bit Integer
DPS/PMI, DPS/PMI
Feedback, Regulator Config

2136

Res Strobe Posit
Displays the electrical position of the resolver at the time a
strobe signal is detected.

Default:
Min:
Max:
Type:
File:
Group:

0
-32768
32767
Non-Linkable, Read Only, 16-bit Integer
DPS/PMI
Regulator Config

2137

Arm Volt FB Cnts
Displays measured armature voltage. A value of 4095
indicates armature voltage - equal to Rated Armature voltage.

Default:
Min:
Max:
Type:
File:
Group:

0
-4095
4095
Non-Linkable, Read Only, 16-bit Integer
DPS/PMI
Regulator Config

No.

Name
Description

Values

Advertising
This manual is related to the following products: