C-42 1756-DMF30 Specific Information

639

Real Out03
Displays output word 03 of the controller communication
format in floating point format. Paired with parameter 638
[Integer Out03], which displays the same data in integer
format.

Default:
Min:
Max:
Type:
File:
Group:

0
-2200000000
2200000000
Linkable, Read-Write, Floating Point
Communication
Logix Outputs

640

Integer Out04
Displays output word 04 of the controller communication
format in integer format. Paired with parameter 641 [Real
Out04], which displays the same data in floating point format.

Default:
Min:
Max:
Type:
File:
Group:

0
-2147483648
2147483648
Linkable, Read-Write, 32-Bit Integer
Communication
Logix Outputs

641

Real Out04
Displays output word 04 of the controller communication
format in floating point format. Paired with parameter 640
[Integer Out04], which displays the same data in integer
format.

Default:
Min:
Max:
Type:
File:
Group:

0
-2147483648
2147483648
Linkable, Read-Write, 32-Bit Integer
Communication
Logix Outputs

642

Integer Out05
Displays output word 05 of the controller communication
format in integer format. Paired with parameter 643 [Real
Out05], which displays the same data in floating point format.

Default:
Min:
Max:
Type:
File:
Group:

0
-2200000000
2200000000
Linkable, Read-Write, Floating Point
Communication
Logix Outputs

643

Real Out05
Displays output word 05 of the controller communication
format in floating point format. Paired with parameter 642
[Integer Out05], which displays the same data in integer
format.

Default:
Min:
Max:
Type:
File:
Group:

0
-2147483648
2147483648
Linkable, Read-Write, 32-Bit Integer
Communication
Logix Outputs

644

Integer Out06
Displays output word 06 of the controller communication
format in integer format. Paired with parameter 645 [Real
Out06], which displays the same data in floating point format.

Default:
Min:
Max:
Type:
File:
Group:

0
-2200000000
2200000000
Linkable, Read-Write, Floating Point
Communication
Logix Outputs

645

Real Out06
Displays output word 06 of the controller communication
format in floating point format. Paired with parameter 644
[Integer Out06], which displays the same data in integer
format.

Default:
Min:
Max:
Type:
File:
Group:

0
-2147483648
2147483648
Linkable, Read-Write, 32-Bit Integer
Communication
Logix Outputs

646

Integer Out07
Displays output word 07 of the controller communication
format in integer format. Paired with parameter 647 [Real
Out07], which displays the same data in floating point format.

Default:
Min:
Max:
Type:
File:
Group:

0
-2200000000
2200000000
Linkable, Read-Write, Floating Point
Communication
Logix Outputs

No.

Name
Description

Values