Rockwell Automation 1756-DMF30 ControlLogix Drive Module User Manual

Page 303

Advertising
background image

Publication 1756-UM522B-EN-P - February 2003

1756-DMF30 Specific Information C-51

1024

SL Tx DirectSel3
Determines the source type for the data transmitted by direct
transmit word 3. The source type selections are: no data,
event, feedback and drive parameter. If drive parameter is
selected, a parameter of the appropriate data format (integer
or real) must be linked to parameter 1147 [SL Dir Int Tx3] or
parameter 1148 [SL Dir Real Tx3]. Configure the selection by
using the Peer Communication window.

Default:

Val 0

No Data

Options:

Val 0
Val 1
Val 2
Val 3
Val 4
Val 5
Val 6
Val 7
Val 8
Val 9
Val 10
Val 11
Val 12
Val 13
Val 14
Val 15
Val 16
Val 17
Val 18
Val 19
Val 20
Val 21
Val 22
Val 23
Val 24
Val 25
Val 26

No Data
SL Multiply
Event P0
Event P1
Event D0
Event D1
Event D2
Event D3
Event Opt0
Event Opt1
Event Status
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Dir Tx Data
Dir Rx Data
E0 Accum
E1 Accum
Opt0 Accum
Opt1 Accum

File:
Group:

SynchLink
SynchLink Config

1030

SL Mult A In
Displays the A Multiplier Input, as a floating point (real) value.
This value is divided by the parameter 1032 [SL Mult Base].
The source of the A Multiplier is determined by the "Rx Direct
Data Selector" (parameters 1011-1014). The possible sources
are: zero, parameter 1054[Dir Int Rx0], parameter 1056 [Dir Int
Rx1], parameter 1058 [Dir Int Rx2], or parameter 1060 [Dir Int
Rx3]. The SynchLink Multiply function takes this input before it
is converted to floating point.

Default:
Min:
Max:
Type:
File:
Group:

0
0
16
Non-Linkable, Read-Only, Floating Point
SynchLink
Multiplier

1031

SL Mult B In
The B Multiplier Input. This must be a floating point (real)
value. The SynchLink Multiply function takes this input after it
is converted to integer.

Default:
Min:
Max:
Type:
File:
Group:

1
0.5
2
Linkable, Read-Write, Floating Point
SynchLink
Multiplier

1032

SL Mult Base
Specifies the base for SynchLink real to integer and integer to
real conversion functions. Determines the resolution of the
conversion results. You must use the same value at the
transmitting node and receiving / multiplying nodes. Enter a
value that will not produce an overflow - the product of this
value and the inputs to the conversion and multiply functions
must be less than 65,536.

Default:
Min:
Max:
Type:
File:
Group:

10000
5000
50000
Non-Linkable, Read-Write, Floating Point
SynchLink
Multiplier

No.

Name
Description

Values