Rockwell Automation 1756-DMF30 ControlLogix Drive Module User Manual

Page 207

Advertising
background image

Publication 1756-UM522B-EN-P - February 2003

1756-DMD30 Specific Information B-127

1212

SL Buf Real Tx25
Provides floating point (real) data for Direct Transmit word 25,
if the data type for word 25 (indicated in parameter 1160 [Tx
Buf Data Type]) is real.

Default:
Min:
Max:
Type:
File:
Group:

0
-2200000000
2200000000
Linkable, Read-Write, Floating Point
SynchLink
Buffered DataOut

1213

SL Buf Int Tx26
Provides integer data for Direct Transmit word 26, if the data
type for word 26 (indicated in parameter 1160 [Tx Buf Data
Type]) is integer.

Default:
Min:
Max:
Type:
File:
Group:

0
-2147483648
2147483648
Linkable, Read-Write, 32-bit Integer
SynchLink
Buffered DataOut

1214

SL Buf Real Tx26
Provides floating point (real) data for Direct Transmit word 26,
if the data type for word 26 (indicated in parameter 1160 [Tx
Buf Data Type]) is real.

Default:
Min:
Max:
Type:
File:
Group:

0
-2200000000
2200000000
Linkable, Read-Write, Floating Point
SynchLink
Buffered DataOut

1215

SL Buf Int Tx27
Provides integer data for Direct Transmit word 27, if the data
type for word 27 (indicated in parameter 1160 [Tx Buf Data
Type]) is integer.

Default:
Min:
Max:
Type:
File:
Group:

0
-2147483648
2147483648
Linkable, Read-Write, 32-bit Integer
SynchLink
Buffered DataOut

1216

SL Buf Real Tx27
Provides floating point (real) data for Direct Transmit word 27,
if the data type for word 27 (indicated in parameter 1160 [Tx
Buf Data Type]) is real.

Default:
Min:
Max:
Type:
File:
Group:

0
-2200000000
2200000000
Linkable, Read-Write, Floating Point
SynchLink
Buffered DataOut

1217

SL Buf Int Tx28
Provides integer data for Direct Transmit word 28, if the data
type for word 28 (indicated in parameter 1160 [Tx Buf Data
Type]) is integer.

Default:
Min:
Max:
Type:
File:
Group:

0
-2147483648
2147483648
Linkable, Read-Write, 32-bit Integer
SynchLink
Buffered DataOut

1218

SL Buf Real Tx28
Provides floating point (real) data for Direct Transmit word 28,
if the data type for word 28 (indicated in parameter 1160 [Tx
Buf Data Type]) is real.

Default:
Min:
Max:
Type:
File:
Group:

0
-2200000000
2200000000
Linkable, Read-Write, Floating Point
SynchLink
Buffered DataOut

1219

SL Buf Int Tx29
Provides integer data for Direct Transmit word 29, if the data
type for word 29 (indicated in parameter 1160 [Tx Buf Data
Type]) is integer.

Default:
Min:
Max:
Type:
File:
Group:

0
-2147483648
2147483648
Linkable, Read-Write, 32-bit Integer
SynchLink
Buffered DataOut

No.

Name
Description

Values