Rockwell Automation 1756-DMF30 ControlLogix Drive Module User Manual

Page 194

Advertising
background image

Publication 1756-UM522B-EN-P - February 2003

B-114 1756-DMD30 Specific Information

1099

SL Buf Int Rx13
Displays the integer value of the Buffered Received Data for
word 13. Data transmitted from one node to another must be
the same data type. This parameter is paired with paramter
1100 [SL Buf Real R13].

Default:
Min:
Max:
Type:
File:
Group:

0
-2147483648
2147483648
Non-Linkable, Read Only, 32-bit Integer
SynchLink
Buffered Data In

1100

SL Buf Real Rx13
Displays the floating point (real) value of the Buffered
Received Data for word 13. Data transmitted from one node to
another must be the same data type. This parameter is paired
with paramter 1099 [SL Buf Int R13].

Default:
Min:
Max:
Type:
File:
Group:

0
-2200000000
2200000000
Non-Linkable, Read Only, Floating Point
SynchLink
Buffered Data In

1101

SL Buf Int Rx14
Displays the integer value of the Buffered Received Data for
word 14. Data transmitted from one node to another must be
the same data type. This parameter is paired with paramter
1102 [SL Buf Real R14].

Default:
Min:
Max:
Type:
File:
Group:

0
-2147483648
2147483648
Non-Linkable, Read Only, 32-bit Integer
SynchLink
Buffered Data In

1102

SL Buf Real Rx14
Displays the floating point (real) value of the Buffered
Received Data for word 14. Data transmitted from one node to
another must be the same data type. This parameter is paired
with paramter 1101 [SL Buf Int R14].

Default:
Min:
Max:
Type:
File:
Group:

0
-2200000000
2200000000
Non-Linkable, Read Only, Floating Point
SynchLink
Buffered Data In

1103

SL Buf Int Rx15
Displays the integer value of the Buffered Received Data for
word 15. Data transmitted from one node to another must be
the same data type. This parameter is paired with paramter
1104 [SL Buf Real R15].

Default:
Min:
Max:
Type:
File:
Group:

0
-2147483648
2147483648
Non-Linkable, Read Only, 32-bit Integer
SynchLink
Buffered Data In

1104

SL Buf Real Rx15
Displays the floating point (real) value of the Buffered
Received Data for word 15. Data transmitted from one node to
another must be the same data type. This parameter is paired
with paramter 1103 [SL Buf Int R15].

Default:
Min:
Max:
Type:
File:
Group:

0
-2200000000
2200000000
Non-Linkable, Read Only, Floating Point
SynchLink
Buffered Data In

1105

SL Buf Int Rx16
Displays the integer value of the Buffered Received Data for
word 16. Data transmitted from one node to another must be
the same data type. This parameter is paired with paramter
1106 [SL Buf Real Rx16].

Default:
Min:
Max:
Type:
File:
Group:

0
-2147483648
2147483648
Non-Linkable, Read Only, 32-bit Integer
SynchLink
Buffered Data In

1106

SL Buf Real Rx16
Displays the floating point (real) value of the Buffered
Received Data for word 16. Data transmitted from one node to
another must be the same data type. This parameter is paired
with paramter 1105 [SL Buf Int Rx16].

Default:
Min:
Max:
Type:
File:
Group:

0
-2200000000
2200000000
Non-Linkable, Read Only, Floating Point
SynchLink
Buffered Data In

No.

Name
Description

Values

Advertising