C-74 1756-DMF30 Specific Information

1229

SL Error Status
Indicates presence of SynchLink faults. This data is visable on
the SynchLink diagnostics tab of the Peer Communication
window.

Default:

0000 0000 0000 0000 0000 0000 0000 0000

Options

Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Bit 16
Bit 17
Bti 18
Bit 19
Bit 20
Bit 21
Bit 22
Bit 23
Bit 24
Bit 25
Bit 26
Bit 27
Bit 28
Bit 29
Bit 30
Bit 31

Sync Loss
Rx Loss
Many BOF Err
Many CRC Err
Pckg Msg Err
CommForm Err
Sys Rev Err
Mult TKeeper
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved

File:
Group:

Utility
Diagnostics

1230

SL CRC Err Accum
Displays the total accumulated number of CRC errors. Clearing
a fault resets this accumulator. This data is visable on the
SynchLink diagnostics tab of the Peer Communication window.

Default:
Min:
Max:
Type:
File:
Group:

0
0
4294967296
Non-Linkable, Read-Only, 32-Bit Integer
Utility
Diagnostics

1231

SL CRC Error
Displays the number of CRC errors that occurred during the last
test (last 8 mS). This data is visable on the SynchLink
diagnostics tab of the Peer Communication window.

Default:
Min:
Max:
Type:
File:
Group:

0
0
4294967296
Non-Linkable, Read-Only, 32-Bit Integer
Utility
Diagnostics

1232

SL BOF Err Accum
Displays the total accumulated number of BOF errors. Clearing
a fault resets this accumulator. This data is visable on the
SynchLink diagnostics tab of the Peer Communication window.

Default:
Min:
Max:
Type:
File:
Group:

0
0
4294967296
Non-Linkable, Read-Only, 32-Bit Integer
Utility
Diagnostics

No.

Name
Description

Values