1756-DMF30 Specific Information C-103

Parameter 1229 [SL Error Status]

This parameter indicates the occurance of SynchLink errors.

Bit

Fault Name

Fault Description

0

Sync Loss

SynchLink communication has failed, after it had
been established.

1

Rx Loss

The receive port is not receiving data, and the receive
port configuration is set to receive data.

2

Many BOF Err

The number of BOF (Beginning Of Frame) errors
accumulated in parameter 1232 [SL BOF Err Accum]
exceeds the value in parameter 1235 [SL BOF Err
Limit].

3

Many CRC Err

The number of CRC (Cycling Ring Checksum) errors
accumulated in parameter 1230 [SL CRC Err Accum]
exceeds the value in parameter 1234 [SL CRC Err
Limit].

4

Pckg Msg Err

The received package sequence number has not
matched for 1.0 S.

5

CommForm Err

The format of received data does not match the
configuration of the receive port.

6

Sys Rev Err

The system revision in received data does not match
the value of parameter 1001 [SynchLink Rev].

7

Mult TKeeper

More than one node on the SynchLink system is
configured as a Time Keeper.