Publication 1756-UM522B-EN-P - February 2003

B-76 1756-DMD30 Specific Information

381

PMI Warning Cnfg
Enter a value to configure the drive's response to a "PMI
Warning" exception event (events enumerated in parameter
2123 [MC Warnings].

• Value 0 - Ignore configures the drive module to

continue running as normal, in response to this event

• Value 1 - Alarm configures the drive module to set the

appropriate alarm bit in response to this event

• Value 2 - FltCoastStop configures the drive module to

perform a coast stop and set the appropriate fault bit in
response to this event

• Value 3 - FltRampStop configures the drive module to

perform a ramp stop and set the appropriate fault bit in
response to this event

• Value 4 - CurLimStp configures the drive module to

perform a current limit stop and set the appropriate
fault bit in response to this event

Default

Val 1

Alarm

Options:

Val 0
Val 1
Val 2
Val 3
Val 4

Ignore
Alarm
FltCoastStop
FltRampStop
FltCurLimStp

File:
Group:

Utility
Fault/Alm Config

382

Lgx OutOfRunCnfg
Enter a value to configure the drive's response to the
ControlLogix processor being in Non-Run mode. Non-Run
modes include Program, Remote-Program and Faulted.

• Value 0 - Ignore configures the drive module to

continue running as normal, in response to this event

• Value 1 - Alarm configures the drive module to set the

appropriate alarm bit in response to this event

• Value 2 - FltCoastStop configures the drive module to

perform a coast stop and set the appropriate fault bit in
response to this event

• Value 3 - FltRampStop configures the drive module to

perform a ramp stop and set the appropriate fault bit in
response to this event

• Value 4 - CurLimStp configures the drive module to

perform a current limit stop and set the appropriate
fault bit in response to this event

Default

Val 2

FltCoastStop

Options:

Val 0
Val 1
Val 2
Val 3
Val 4

Ignore
Alarm
FltCoastStop
FltRampStop
FltCurLimStp

File:
Group:

Utility
Fault/Alm Config

No.

Name
Description

Values

ATTENTION

!

Risk of injury or equipment damage exists. Parameter 382 [Lgx
OutOfRunCnfg] lets you determine the action of the drive if communications
are disrupted. By default this parameter causes the drive to fault and coast to
a stop. You can set this parameter so that the drive continues to run.
Precautions should be taken to ensure that the setting of this parameter does
not create a hazard of injury or equipment damage.