Rockwell Automation 1756-DMF30 ControlLogix Drive Module User Manual

Page 143

Advertising
background image

Publication 1756-UM522B-EN-P - February 2003

1756-DMD30 Specific Information B-63

308

Output Current
Displays the actual RMS value of the motor current as
determined from the current sensors.

Units:
Default:
Min:
Max:
Type:
File:
Group:

Amps
0
-6000
6000
Non-Linkable, Read Only, Floating Point
Monitor, DPS/PMI
Metering, Feedback

314

VPL Firmware Rev
Indicates the major and minor revision levels of the drive
module’s Velocity Position Loop (VPL) firmware.

Default:
Min:
Max:
Type:
File:
Group:

x.xxx
0.001
65.255
Non-Linkable, Read Only, 16-bit Integer
Monitor
Drive Data

315

VPL Build Number
Indicates the build number of the drive module’s Velocity
Position Loop (VPL) firmware.

Default:
Min:
Max:
Type:

x
1
10000
Non-Linkable, Read Only, 16-bit Integer

316

SynchLink Status
Indicates status of SynchLink functions.

Default:

0000 0000 0000 0000 0000 0000 0000 0000

Options:

Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Bit 16
Bit 17
Bit 18
Bit 19
Bit 20
Bti 21
Bit 22
Bit 23
Bit 24
Bit 25
Bit 26
Bit 27
Bit 28
Bit 29
Bit 30
Bit 31

Reserved
Reserved
Reserved
In Sync
Tx Active
Rx Active
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Rx Data Enbl
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved

File:
Group:

Utility
Diagnostics

No.

Name
Description

Values

Advertising
This manual is related to the following products: