Rockwell Automation 1756-DMF30 ControlLogix Drive Module User Manual

Page 229

Advertising
background image

Publication 1756-UM522B-EN-P - February 2003

1756-DMD30 Specific Information B-149

2186

Min Field Curr
Set to the minimum amps value on the motor nameplate.

Units:
Default:
Min:
Max:
Type:
File:
Group:

Amps
0.10
0.01
99.99
Non-Linkable, Read-Write, 16-bit Integer
DPS/PMI
Motor Data

2187

Field Loss Amps
Set the under-current trip point for field loss detection in the
PMI processor.

Units:
Default:
Min:
Max:
Type:
File:
Group:

Amps
0.10
0.01
99.99
Non-Linkable, Read-Write, 16-bit Integer
Speed Control
Regulator

2188

Field Off Delay
Set the amount of time the field will remain energized after a
fault condition. (1 to 300S)

Units:
Default:
Min:
Max:
Type:
File:
Group:

Sec
180
1
300
Non-Linkable, Read-Write, 16-bit Integer
DPS/PMI
Motor Data

2189

Motor Inertia
The time, in seconds, for the motor (not coupled to load) to
accelerate from zero to base sped, at rated motor torque. The
drive calculates Motor Inertia during the auto-tune procedure.

Units:
Default:
Min:
Max:
Type:
File:
Group:

Sec
0.4
0.01
655
Linkable, Read-Write, Floating Point
DPS/PMI
Drive Config

2190

Total Inertia
The time, in seconds, for a motor coupled to a load to
accelerate from zero to base speed, at rated motor torque. The
drive calculates Total Inertia during the auto-tune procedure.

Units:
Default:
Min:
Max:
Type:
File:
Group:

Sec
2
0.01
655
Linkable, Read-Write, Floating Point
DPS/PMI
Drive Config

No.

Name
Description

Values