Publication 1756-UM522B-EN-P - February 2003

1756-DMD30 Specific Information B-109

1043

SL Rx D0 Latch
Displays received event D0 latch data, if direct received data is
configured to be event D0 latch data by the Rx Direct Data
Selector (parameters 1011-1014). Configure this selection by
using the Peer Communication window.

Default:
Min:
Max:
Type:
File:
Group:

0
-2147483648
2147483648
Non-Linkable, Read Only, 32-bit Integer
SynchLink
Event Data

1044

SL Rx D1 Latch
Displays received event D1 latch data, if direct received data is
configured to be event D1 latch data by the Rx Direct Data
Selector (parameters 1011-1014). Configure this selection by
using the Peer Communication window.

Default:
Min:
Max:
Type:
File:
Group:

0
-2147483648
2147483648
Non-Linkable, Read Only, 32-bit Integer
SynchLink
Event Data

1045

SL Rx D2 Latch
Displays received event D2 latch data, if direct received data is
configured to be event D2 latch data by the Rx Direct Data
Selector (parameters 1011-1014). Configure this selection by
using the Peer Communication window.

Default:
Min:
Max:
Type:
File:
Group:

0
-2147483648
2147483648
Non-Linkable, Read Only, 32-bit Integer
SynchLink
Event Data

1046

SL Rx D3 Latch
Displays received event D3 latch data, if direct received data is
configured to be event D3 latch data by the Rx Direct Data
Selector (parameters 1011-1014). Configure this selection by
using the Peer Communication window.

Default:
Min:
Max:
Type:
File:
Group:

0
-2147483648
2147483648
Non-Linkable, Read Only, 32-bit Integer
SynchLink
Event Data

1047

SL Rx Opt0 Regis
Displays received registration data from feedback option 1
(high resolution encoder daughter card), if direct received data
is configured to be feedback option 1 registration data by the
Rx Direct Data Selector (parameters 1011-1014). Configure
this selection by using the Peer Communication window.

Default:
Min:
Max:
Type:
File:
Group:

0
-2147483648
2147483648
Non-Linkable, Read Only, 32-bit Integer
SynchLink
Event Data

1048

SL Rx Opt1 Regis
Displays received registration data from feedback option 0
(high resolution encoder daughter card), if direct received data
is configured to be feedback option 0 registration data by the
Rx Direct Data Selector (parameters 1011-1014). Configure
this selection by using the Peer Communication window.

Default:
Min:
Max:
Type:
File:
Group:

0
-2147483648
2147483648
Non-Linkable, Read Only, 32-bit Integer
SynchLink
Event Data

1054

SL Dir Int Rx0
Displays the integer value of the Direct Received Data for word
0. Data transmitted from one node to another must be the
same data type. This parameter is paired with paramter 1055
[SL Dir Real Rx0].

Default:
Min:
Max:
Type:
File:
Group:

0
-2147483648
2147483648
Non-Linkable, Read Only, 32-bit Integer
SynchLink
Event Data

1055

SL Dir Real Rx0
Displays the floating point (real) value of the Direct Received
Data for word 0. Data transmitted from one node to another
must be the same data type. This parameter is paired with
paramter 1054 [SL Dir Int Rx0].

Default:
Min:
Max:
Type:
File:
Group:

0
-2200000000
2200000000
Non-Linkable, Read Only, Floating Point
SynchLink
Direct Data

No.

Name
Description

Values