Publication 1756-UM522B-EN-P - February 2003

1756-DMD30 Specific Information B-89

658

Integer Out13
Displays output word 13 of the controller communication
format in integer format. Paired with parameter 659 [Real
Out13], which displays the same data in floating point format.

Default:
Min:
Max:
Type:
File:
Group:

0
-2147483648
2147483648
Non-Linkable, Read Only, 32-bit Integer
Communication
Logix Outputs

659

Real Out13
Displays output word 13 of the controller communication
format in floating point format. Paired with parameter 658
[Integer Out13], which displays the same data in integer
format.

Default:
Min:
Max:
Type:
File:
Group:

0
-2200000000
2200000000
Non-Linkable, Read Only, Floating Point
Communication
Logix Outputs

660

Integer Out14
Displays output word 14 of the controller communication
format in integer format. Paired with parameter 661 [Real
Out14], which displays the same data in floating point format.

Default:
Min:
Max:
Type:
File:
Group:

0
-2147483648
2147483648
Non-Linkable, Read Only, 32-bit Integer
Communication
Logix Outputs

661

Real Out14
Displays output word 14 of the controller communication
format in floating point format. Paired with parameter 660
[Integer Out14], which displays the same data in integer
format.

Default:
Min:
Max:
Type:
File:
Group:

0
-2200000000
2200000000
Non-Linkable, Read Only, Floating Point
Communication
Logix Outputs

662

Integer Out15
Displays output word 15 of the controller communication
format in integer format. Paired with parameter 663 [Real
Out15], which displays the same data in floating point format.

Default:
Min:
Max:
Type:
File:
Group:

0
-2147483648
2147483648
Non-Linkable, Read Only, 32-bit Integer
Communication
Logix Outputs

663

Real Out15
Displays output word 15 of the controller communication
format in floating point format. Paired with parameter 662
[Integer Out15], which displays the same data in integer
format.

Default:
Min:
Max:
Type:
File:
Group:

0
-2200000000
2200000000
Non-Linkable, Read Only, Floating Point
Communication
Logix Outputs

664

Lgx Comm Format
Indicates the Controller to Drive Module communication
format.

• A value of 16 indicates Velocity Control

• A value of 17 indicates Position Control

• A value of 18 indicates User-Defined

• A value of 32 indicates Custom User-Defined

Default:
Min:
Max:
Type:
File:
Group:

0
0
4294967296
Non-Linkable, Read Only, 32-bit Integer
Communication
Commands

No.

Name
Description

Values

Advertising