Publication 1756-UM522B-EN-P - February 2003

1756-DMF30 Specific Information C-55

1056

SL Dir Int Rx1
Displays the integer value of the Direct Received Data for word
1. Data transmitted from one node to another must be the
same data type. This parameter is paired with paramter 1057
[SL Dir Real Rx1].

Default:
Min:
Max:
Type:
File:
Group

0
-2147483648
2147483648
Non-Linkable, Read-Only, 32-Bit Integer
SynchLink
Direct Data

1057

SL Dir Real Rx1
Displays the floating point (real) value of the Direct Received
Data for word 1. Data transmitted from one node to another
must be the same data type. This parameter is paired with
paramter 1056 [SL Dir Int Rx1].

Default:
Min:
Max:
Type:
File:
Group:

0
-2200000000
2200000000
Non-Linkable, Read-Only, Floating Point
SynchLink
Direct Data

1058

SL Dir Int Rx2
Displays the integer value of the Direct Received Data for word
2. Data transmitted from one node to another must be the
same data type. This parameter is paired with paramter 1059
[SL Dir Real Rx2].

Default:
Min:
Max:
Type:
File:
Group:

0
-2147483648
2147483648
Non-Linkable, Read-Only, 32-Bit Integer
SynchLink
Direct Data

1059

SL Dir Real Rx2
Displays the floating point (real) value of the Direct Received
Data for word 2. Data transmitted from one node to another
must be the same data type. This parameter is paired with
paramter 1058 [SL Dir Int Rx2].

Default:
Min:
Max:
Type:
File:
Group:

0
-2200000000
2200000000
Non-Linkable, Read-Only, Floating Point
SynchLink
Direct Data

1060

SL Dir Int Rx3
Displays the integer value of the Direct Received Data for word
3. Data transmitted from one node to another must be the
same data type. This parameter is paired with paramter 1061
[SL Dir Real Rx3].

Default:
Min:
Max:
Type:
File:
Group:

0
-2147483648
2147483648
Non-Linkable, Read-Only, 32-Bit Integer
SynchLink
Direct Data

1061

SL Dir Real Rx3
Displays the floating point (real) value of the Direct Received
Data for word 3. Data transmitted from one node to another
must be the same data type. This parameter is paired with
paramter 1060 [SL Dir Int Rx3].

Default:
Min:
Max:
Type:
File:
Group:

0
-2200000000
2200000000
Non-Linkable, Read-Only, Floating Point
SynchLink
Direct Data

1073

SL Buf Int Rx00
Displays the integer value of the Buffered Received Data for
word 0. Data transmitted from one node to another must be
the same data type. This parameter is paired with paramter
1074 [SL Buf Real Rx00].

Default:
Min:
Max:
Type:
File:
Group:

0
-2147483648
2147483648
Non-Linkable, Read-Only, 32-Bit Integer
SynchLink
Buffered Data In

1074

SL Buf Real Rx00
Displays the floating point (real) value of the Buffered
Received Data for word 0. Data transmitted from one node to
another must be the same data type. This parameter is paired
with paramter 1073 [SL Buf Int Rx00].

Default:
Min:
Max:
Type:
File:
Group:

0
-2200000000
2200000000
Non-Linkable, Read-Only, Floating Point
SynchLink
Buffered Data In

No.

Name
Description

Values