Rockwell Automation 1756-DMF30 ControlLogix Drive Module User Manual

Page 223

Advertising
background image

Publication 1756-UM522B-EN-P - February 2003

1756-DMD30 Specific Information B-143

2123

MC Warnings
Indicates Motor-Control warnings. These bits latch when a
Motor-Control warning event occurs. They stay latched until
bit 19 [Clear Fault] of parameter 152 [Applied LogicCmd] or bit
19 [Clr Drv Wrn] of parameter 166 [Motor Ctrl Cmmd] is set. If
the warning condition remains present, the identifying bit is
set again.

Default:

0000 0000 0000 0000 0000 0000 0000 0000

Options:

Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
Bit 16
Bit 17
Bit 18
Bit 19
Bit 20
Bit 21
Bit 22
Bit 23
Bit 24
Bit 25
Bit 26
Bit 27
Bit 28
Bit 29
Bit 30
Bit 31

BrdgNotFirng
Low AC Line
Reserved
LineSyncLoss
Curr Ref Lim
ID TestAbort
Fld OvrCurr
Arm Fdbk Rev
CT Fdbk Rev
Reserved
Reserved
Reserved
PMI Fan Loss
Rail IO Comm
PMI CommSync
PMI Comm
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved

File:
Group:

Utility, DPS/PMI
Diagnostics, Feedback

No.

Name
Description

Values