Publication 1756-UM522B-EN-P - February 2003

1756-DMF30 Specific Information C-35

384

Lgx Closed Cnfg
Enter a value to configure the Drive Module's response to the
controller closing the Controller to Drive Module connection.

• Value 0 - Ignore configures the drive to continue

running, as normal, when this event occurs

• Value 1 - Alarm configures the drive to continue

running and set the appropriate alarm bit when this
event occurs

• Value 2 - FltCoastStop configures the drive to perform a

coast stop and set the appropriate fault bit, in response
this event.

Default:

Val 2

FltCoastStop

Options:

Val 0
Val 1
Val 2

Ignore
Alarm
FltCoastStop

File:
Group:

Utility
Fault/Alm Config

385

Lgx LinkChngCnfg
Enter a value to configure the Drive Module's response to
Controller to Drive Module default links being removed. A
default link is a link automatically set up when a
communication format is selected for the Controller to Drive
Module connection.

• Value 0 - Ignore configures the drive to continue

running, as normal, when this event occurs

• Value 1 - Alarm configures the drive to continue

running and set the appropriate alarm bit when this
event occurs

• Value 2 - FltCoastStop configures the drive to perform a

coast stop and set the appropriate fault bit, in response
this event.

Default:

Val 2

FltCoastStop

Options:

Val 0
Val 1
Val 2

Ignore
Alarm
FltCoastStop

File:
Group:

Utility
Fault/Alm Config

No.

Name
Description

Values

ATTENTION

!

Risk of injury or equipment damage exists. Parameter 384 [Lgx Closed
Cnfg] lets you determine the action of the drive if communications are
disrupted. By default this parameter causes the drive to fault and coast
to a stop. You can set this parameter so that the drive continues to run.
Precautions should be taken to ensure that the setting of this parameter
does not create a hazard of injury or equipment damage.

ATTENTION

!

Risk of injury or equipment damage exists. Parameter 385 [Lgx
LinkChngCnfg] lets you determine the action of the drive if
communications are disrupted. By default this parameter causes the
drive to fault and coast to a stop. You can set this parameter so that the
drive continues to run. Precautions should be taken to ensure that the
setting of this parameter does not create a hazard of injury or equipment
damage.