Nortel Networks 8000 User Manual

Page 229

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

7 LAPB and X.25 configuration

Nortel Secure Router 8000 Series

Configuration -WAN Access

x25 map { compressedtcp protocol-address | ip protocol-address } * x121-address

x.121-address idle-timer minutes

The command configures the maximum idle time for SVC associated with an address

mapping.

Step 5

Run:

x25 vc-per-map count

The command configures the maximum number of SVCs associated with all address

mappings on the interface.

Step 6

Run:

x25 map { compressedtcp protocol-address | ip protocol-address }* x121-address

x.121-address vc-per-map count

The command configures the maximum number of SVCs associated with an address mapping.

Step 7

Run:

x25 receive-threshold count

The command configures the packet acknowledgment value.

Step 8

Specify the number of closed user group (CUG).

Run the

x25 call-facility closed-user-group

number

command to specify the number of

the CUG.

Run the

x25 map

{

compressedtcp

protocol-address

|

ip

protocol-address

} *

x121-address

x.121-address

closed-user-group

number

command to configure the X.25

mapping.

Step 9

Configure flow-control parameters when a call is initiated:

Run one of the following commands to configure packet size.

- x25 call-facility packet-size

input-packet output-packet

-

x25 map

{

compressedtcp

protocol-address

|

ip

protocol-address

} *

x121-address

x.121-address

packet-size

input-packet output-packet

Run one of the following commands to configure window size.

- x25 call-facility window-size

input-window-size output-window-size

-

x25 map

{

compressedtcp

protocol-address

|

ip

protocol-address

} *

x121-address

x.121-address

window-size

input-window-size output-window-size

Step 10

Run one of the following commands to configure reverse charging when a call is initiated.

x25 call-facility reverse-charge-request

x25 map

{

compressedtcp

protocol-address

|

ip

protocol-address

} *

x121-address

x.121-address

reverse-charge-request

Step 11

Run one of the following command to receive calls with reverse charging requests.

x25 reverse-charge-accept

x25 map

{

compressedtcp

protocol-address

|

ip

protocol-address

} *

x121-address

x.121-address

reverse-charge-accept

Step 12

Run one of the following commands to configure threshold when a call is initiated.

7-26

Nortel Networks Inc.

Issue 5.3 (30 March 2009)

Advertising