4 POS and CPOS interface configuration

Nortel Secure Router 8000 Series

Configuration -WAN Access

A

Before configuring the synchronous serial interface, you need to run the

shutdown command

to disable the interface. After the configuration, you need to run the

undo shutdown

command to start the interface to validate the configuration.

4.5.2 Configuring attribute parameters of synchronous serial

interface

Do as follows on the routers:

Step 1 Run:

system-view

The system view appears.

Step 2 Run:

interface serial interface-number

The synchronous serial interface view appears.

Step 3 (optional) Run:

crc { 16 | 32 }

The command configures the CRC check of 16 bits or 32 bits.

By default, the synchronous serial interface uses the CRC check of 16 bits.

CÛ NOTE

Only the synchronous interface channelized by the RTP1CPE1 and RTP1CPT1 interface cards supports
the crc command. By default, low-speed CPOS interface cards use the 16-bit CRC check.

Step 4 (optional) Run:

mtu mtu

The MTU is configured.

By default, the MTU value is 1500 bytes.

When the local synchronous serial interface and that of the remote device communicate with

each other, the attribute parameters on both ends should be consistent.

—End

4.5.3 Configuring link layer protocol of synchronous serial

interface

Do as follows on the routers:

Step 1 Run:

system-view

4-24

Nortel Networks Inc.

Issue 5.3 (30 March 2009)