2 Serial interface configuration

Nortel Secure Router 8000 Series

Configuration -WAN Access

system-view

The system view appears.

Step 2 Run:

interface serial interface-number

The serial interface view appears.

Step 3 Run:

detect dcd

The command enables DCD signal detection.

If the DCD signal detection of the interface is disabled, the system detects only when the

serial interface is connecting to the cable and reports the state (Up or Down) of the interface.

If the DCD signal is invalid, the system considers the interface as Down.

By default, DCD signal detection is enabled for synchronous serial interfaces.

—End

Configuring DSR signal detection

Do as follows on the routers:

Step 1 Run:

system-view

The system view appears.

Step 2 Run:

interface serial interface-number

The serial interface view appears.

Step 3 Run:

detect dsr-dtr

The command enables DSR signal detection.

If the DSR signal detection of the interface is disabled, the system detects when the serial

interface is connecting to the cable and reports the state (Up and Down) of the interface. If the
DSR signal is invalid, the system considers the interface as Down.

By default, DSR the synchronous serial interface enables signal detection.

—End

2.2.6 Configuring link coding mode

Do as follows on the routers:

Step 1 Run:

system-view

2-6

Nortel Networks Inc.

Issue 5.3 (30 March 2009)