Nortel Secure Router 8000 Series

Configuration -WAN Access

8 Frame relay configuration

The command configures the timeout period (determined by T392) for the DCE device to

wait for a status request packet and the LMI N391 parameters on the DTE device.

Step 5

Run:

fr Imi n392dce n392-value

The command configures the DCE N392 parameter.

Step 6

Run:

fr Imi n393dce n393-value

The command configures the DCE N393 parameter.

—End

8.5.4 Checking the configuration

Run the following commands to check the previous configuration.

Action

Command

Check statistics about FR LMI

packets.

display fr Imi-info

[

interface

interface-type

interface-number ]

Run the

display fr Imi-info

command. When statistics about FR LMI packets appear the

configuration succeeds. For example:

<Nortel> display fr Imi-info

Frame relay LMI statistics for interface MFR6/0/0 (DTE, Q933)

T391DTE = 10 (hold timer 10)

N391DTE = 5, N392DTE = 3, N393DTE = 4

out status enquiry = 0, in status = 0

status timeout = 0, discarded messages = 0

Frame relay LMI statistics for interface Serial6/0/0 (DCE, Q933)

T392DCE = 15, N392DCE = 3, N393DCE = 4

in status enquiry = 250, out status = 250

status enquiry timeout = 0, discarded messages = 15

8.6 Configuring frame relay switching

8.6.1 Establishing the configuration task

Applicable environment

When data exchange is required on a FR switch, you need to configure the FR switching

function.

You can use a router to implement the FR switching, which you can configure by the FR
switching route and the FR switching PVC.

Issue 5.3 (30 March 2009)

Nortel Networks Inc.

8-23