Fault analysis, Troubleshooting procedure, 3 x.25 protocol cannot enter the up status – Nortel Networks 8000 User Manual

Page 279: Fault description, 4 x.25 protocol is up, vc cannot be established, Fault dnalysis, 3 x.25 protocol cannot enter the up status -76, X.25 protocol cannot enter the up status, X.25 protocol is up, vc cannot be established

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

7 LAPB and X.25 configuration

Nortel Secure Router 8000 Series

Configuration -WAN Access

Fault analysis

The possible cause is that the maximum frame size of this end may be too small. Set a larger

value of maximum frame size.

Troubleshooting procedure

Do as follows on the routers:

Step 1

Enable the debugging. You can find that one end discards the received frames without

transmitting it to the X.25 packet layer.

Step 2

Modify the MTU on the end.

—End

7.9.3 X.25 Protocol cannot enter the up status

Fault description

LAPB is in "Connect" state, but the X.25 protocol cannot enter the "UP" state for a long time.

Fault analysis

The possible causes are:

You have configured the local working mode incorrectly. That is, the working modes on

both the ends of a connection are the same. The modes may be DTE or DCE.

The X.25 modulo settings are di^erent on two ends.

Troubleshooting procedure

Do as follows on the routers:

Step 1

Change operation mode of the interfaces.

Step 2

Modify the X.25 modulus.

—End

7.9.4 X.25 Protocol is up, VC cannot be established

Fault description

The X.25 protocol is Up, but the VC cannot be set up.

Fault dnalysis

The possible causes are as follows:

The local X. 121 address is not configured.

The address mapping to the peer is not configured.

The opposite X.121 address is not configured.

7-76

Nortel Networks Inc.

Issue 5.3 (30 March 2009)