ValveSight™ Diagnostics DTM Manual for Logix MD+ Positioner with HART®

FCD-

LGENSF0014-00

© Flowserve Corporation

191


ID, the date the file was saved, and the file name for each file.


Break Away Information
The Partial Stroke Test Settings area contains the information used to run the partial stroke
test and the pass/fail criteria. This information is shown for each file in a side-by-side
comparison.
The Break Away Information area shows the values for the results of the partial stroke test
including the time until initial movement, pressure at break away, time to target and pass or
fail results. It also shows the difference between the values from the first file compared to
the second file.


PST Settings
The PST Settings area contains the information used to run the PST test and other
information that may affect the results. This information is shown for each file in a side-by-
side comparison.