Flowserve Logix MD+ ValveSight User Manual

Page 94

Advertising
background image

ValveSight™ Diagnostics DTM Manual for Logix MD+ Positioner with HART®

FCD-

LGENSF0014-00

© Flowserve Corporation

94


limit.

Implications: Low supply pressure can cause poor valve response or

positioner failure. The minimum recommended supply pressure for
proper operation is 1.3 bar (19 PSI).

Possible Solutions: Regulate the supply pressure at the positioner

above 1.3 bar (19 PSI). Ensure system air/gas supply is
adequate. Repair kinked or restricted supply tubing. Check for
pneumatic leaks in the actuator and actuator tubing. Recalibrate
pressure sensors. Check the pressure sensor board connections and
replace pressure sensor board if necessary.

Actuation Ratio

Definition: The force required to control the system is close to the

maximum available force.

Implications: Actuation Ratio is based on the ratio of available force to

the required force to actuate. Control may be lost if this ratio reaches
100%. It is affected by the process load, friction, spring force, and
available supply pressure.

Possible Solutions: Increase the supply pressure. Reduce the

friction. Check the actuator spring. Resize the actuator. Adjust user
set limits.

Spring Fail

Definition: Upon loss of air supply, the valve may not move to the fail-

safe position.

Implications: The spring alone is not adequate to overcome the friction

and process load in the system. The system is relying on pneumatic
force to actuate in the direction the spring is pushing. The failsafe
spring may have failed, or it was not sized properly for the application.
Friction or process load may have increased.

Possible Solutions: Repair or replace actuator spring. Check for high

friction. Reduce process load.

Pneumatic Leak

Definition: The positioner has detected a leak in the actuation

assembly.

Implications: Leakage from the actuator can cause decreased

responsiveness and excessive air/gas consumption.

Possible Solutions: Repair pneumatic leaks at the tubing junctions

and actuator seals. Check spool valve for excessive wear.