Implications: Each cycle represents two reversals of the direction of

valve movement. The cycle counting criterion and count limit are set by
the user to track the usage of the valve.

Possible Solutions: Follow routine procedures for maintenance when

the limit is reached such as checking the packing tightness, and
checking linkages for wear, misalignment, and tightness. After
maintenance, reset the cycle accumulator.

Valve Travel

Definition: The total accumulated valve travel limit has been

exceeded.

Implications: The travel is accumulated in both directions. The travel

counting criterion and limit are set by the user to track the usage of the
valve.

Possible Solutions: Follow routine procedures for maintenance when

the limit is reached such as checking the packing tightness, and
checking linkages for wear, misalignment, and tightness. After
maintenance, reset the travel accumulator.

Actuator Cycles

Definition: The actuator cycle limit has been exceeded.

Implications: Each cycle represents two reversals of the direction of

valve movement. The cycle counting criterion and count limit are set by
the user to track the usage of the valve.

Possible Solutions: Follow routine procedures for maintenance when

the limit is reached such as checking the actuator seals and
lubrication. After maintenance, reset the travel accumulator.

Actuator Travel

Definition: The total accumulated actuator travel limit has been

exceeded.

Implications: The travel is accumulated in both directions. The travel

counting criterion and limit are set by the user to track the usage of the
valve.

Possible Solutions: Follow routine procedures for maintenance when

the limit is reached such as checking the actuator seals and
lubrication. After maintenance, reset the travel accumulator.

Bellows Cycles

Definition: The bellows cycle limit has been exceeded.

Implications: The bellows may be reaching the end of its fatigue

life. Each cycle represents two reversals of the direction of bellows
movement. The cycle counting criterion and count limit are set by the
user to track the usage of the valve.

Possible Solutions: Follow routine procedures for maintenance when

the limit is reached such as checking bellows for cracking or
leaking. After maintenance, reset the cycle accumulator.

Bellows Travel

Definition: The bellows cycle limit has been exceeded.