TOHO ELECTRONICS TTM200 User Manual

Page 139

Advertising
background image

48-7009-E

5-69

■ The diagram below shows an example of a program run with StEPN

8.

STEP1

STEP2

STEP3

STEP4

STEP5

STEP6

STEP7

STEP8

Operation

Start

Operation

End

PV

Operation Stop

Manipulation

Operation Start

Manipulation

STOP

Operation

38

0025

%1

48

0015

%1

83

0032

%2

96

0020

%2

BANK1

RMP

10

P1

4.0

o3F

20

5

BANK1

RMP

10

o3F

BANK1

RMP

10

o3F

BANK1

RMP

10

o3F

BANK2

RMP

5

o3F

BANK2

RMP

5

BANK1

RMP

10

BANK3

RMP

30

BANK0

RMP

P1

3.0

o3F

0

0

BANK0

RMP

P1

2.0

10

2

P1

3.0

0

0

P1

4.0

20

5

P1

4.0

20

5

P1

4.0

20

5

P1

4.0

20

5

P1

2.0

10

2

P1

2.0

10

2

SV1

50℃

TIM1

00:30

ST1BK

BANK1

SV2

100℃
TIM2

00:40

ST2BK

BANK1

SV3

150℃
TIM3

00:50

ST3BK

BANK1

SV4

200℃
TIM4

01:00

ST4BK

BANK1

SV5

150℃
TIM5

00:30

ST5BK

BANK2

SV6

100℃
TIM6

00:40

ST6BK

BANK2

SV7

150℃
TIM7

00:50

ST7BK

BANK1

SV8

20℃

TIM8

00:10

ST8BK

BANK3

St*bK

tIM*

SV*

SV

139

0041

%3

147

0025

%3

181

0049

%4

191

0031

%4

151

0016

%5

158

0022

%5

101

0021

%6

104

00 32

%6

148

00 39

%7

150

0029

%7

28

0004

%8

38

0006

%8

20

PROG

%0

22

END

%0

22

PROG

%0

o2F

o2F

o2F

o2F

o2F

o2F

o2F

o2F

o2F

o2F

BANK3

RMP

P1

3.0

0

0

o2F

In the process

of ending

Operation

Suspended

In Program Operation

Operation

Suspended

18

18

18

18

18

o3F

18

o3F

18

o3F

18

o3F

18

18

6

o3F

18

6

*** Time Signal Output Setting ***
*(SET14)tMF1=15, (SET14)tSV1=0, (SET14)oNt1=00:15
  Step Start
*(SET6)o2F=6
  When Bank 2, o2F=Timer 1 on Delay Output. Other banks are Event Output (nofunction)
*(SET7)o3F=18
  End Output
*** Program Function Setting ***
*(SET21)C/P=1, (SET21) PGMD=3, (SET21)PoC=0, (SET21)H/MP=2, (SET21)WAIt=5
  Program 2 (w/ Power Failure Compensation), 2: Soak Time 2 (Hr./Min.)
*(SET22) StEPN=8, (SET22) StRSt=1, (SET22) ENdSt=8, (SET22)RUNP=1
*** Other Settings ***
*Set to (SET4) Bank=0. Also, "0" is assumed when BANK switchover is ON by DI.

2

2

2

2

2

2

2

2

2

bNK01

5

5

30

(SET21)PGMd=3
Setting Operation
Continuation

oUt2

oUt3

bNK02

bNK03

bNK04

bNK05

bNK06

bNK07

bNK08

bNK09

bNK10

bNK11

bNK12

bNK13

bNK14

bNK15

bNK16

Operation Suspended
(SET4)bANK=0
DI(nonActive)

Program Operation
Display Indication

Time Signal Output

Reference

Bank No.

SET20(bNK)

Setting Value

Operation Suspended
(SET4)bANK=0
DI(nonActive)

SET22(PRoG)

Setting Value

 Time Signal Output Setting

• (SET14)tMF1=15, (SET14)tSV1=0, (SET14)oNt1=00:15

Step Start

• SET6)o2F=6

When Bank 2, o2F=Timer 1 on Delay Output. Other banks are Event Output (nofunction)

• (SET7)o3F=18

End Output

 Program Function Setting

• (SET21)C/P=1, (SET21) PGMD=3, (SET21) PoC=0, (SET21) H/MP=2, (SET21) WAIt=5

Program 2 (w/ Power Failure Compensation), 2: Soak Time 2 (Hr./Min.)

• (SET22) StEPN=8, (SET22) StRSt=1, (SET22) ENdSt=8, (SET22)RUNP=1

Number-of-use-step: 8, repetitive start step: 1, repetitive end step: 8, execution count: 1

 Other Settings

• Set to (SET4) Bank=0. Also, "0" is assumed when BANK switchover is ON by DI.