6.9 Communication function setting

■ Communication protocol setting

SEt17

CoM

Setting content

Initial value

1

PRt

Press the MODE key for making a setting effective (including reverse feed).

0

0

TOHO protocol

1

MODBUS protocol (RTU mode)

2

MODBUS protocol (ASCII mode)


Set the communication protocol (communication procedure).

For details of communication, see “TTM-200 series operation manual - communications.”


■ Communication parameter setting

SEt17

CoM

Setting content

Initial value

2

CoM

***1

Stop bit length 1 bit

b8N2

***2

Stop bit length 2 bits

**N*

Parity none

**o*

Parity odd No.

**E*

Parity even No.

*7**

Data length 7 bits

*8**

Data length 8 bits

N***

BCC check nonexistent (settable for TOHO protocol)

b***

BCC check existent (settable for TOHO protocol)

For MODBUS (RTU)
Settable only with 8N2, 8N2, 8o1, 8o2, 8E1 and 8E2.

For MODBUS (ASCII)

Settable only with 7N1,7N2,7o1,7o2,7E1,7E2,

8N1,8N2,8o1,8o2,8E1,8E2


The following is set for communication data: stop bit length, parity and BCC check existent/nonexistent.

For details of communication, see “TTM-200 series operation manual - communications.”

■ Communication speed setting

SEt17

CoM

Setting content

Initial value

3

bPS

2.4

2400 bps

9.6

4.8

4800 bps

9.6

9600 bps

19.2

19200 bps

38.4

38400 bps


Set the communication speed.
The term bps (bits per second) refers to the number of bits allowed in communication in a second.

For details of communication, see “TTM-200 series operation manual - communications.”