1 flow of setting mode, Flow of setting mode -2 – TOHO ELECTRONICS TTM200 User Manual

Page 43

Advertising
background image

48-7009-E

4-2

4.1 Flow of setting mode



PROG

25

0

25

0

INP1

The equipment does not operate for
about 4 seconds after power-on.

At SET 21 program mode setting
In (C/P = 0) constant value run mode

Power-on

Initial screen

Constant value run mode screen

4 seconds

4 seconds

At SET 21 program mode setting
In (C/P

0) program run mode

Program run mode screen

The following is possible in this mode: display of PV value
(present value), setting of SV value (setting value) which is
the target value of control, display of remaining time
monitor for timer 1, 2 and 3, display of priority screens 1 to
16, display of the bank No. that is presently set and various
functions in effect (output, CT, communication, DI, AI, etc.)

The following is possible in this mode: display of PV
value (present value), program run status for SV value,
display of remaining time monitor for timer 1, 2 and 3,
display of priority screens 1 to 16, display of the bank
No. that is presently set and various functions in effect
(output, CT, communication, DI, AI, etc.)

MODE key for
2 seconds

At SET 21 program mode setting
Transition is made one another
according to the C/P setting.

MODE key for
2 seconds

Setting item selection screen (SET 01 - SET 23) (See the page 6-1 and thereafter.)
Various parameters regarding SET 01 - SET 23 are set.
SET 21 and 22 are settings for the program run.

MODE key

Parameter setting screen in each SET
Various parameters are set. (See pages 6-2 to 6-xx.)

* Using the MODE key, parameter screens for each setting mode is disp layed in sequence, and the screen

returns to the SET** screen.

* Using the ▲/▼ key, the setting item selection screens SET 01 to SET 23 is displayed in sequence.
(In case of no function registered, the corresponding screen is not displayed.)
(For program run mode, see pages 6-13 to 6-xx.)
* The screen moves back to the operating mode screen when holding the MODE key pressed for 2 seconds in

parameter screens for each SET screen.

Blind setting screen

The screen for setting items to be “blinded”
(non-displayed) by using parameters appears.
For details, see pages 4-27 and 28.

MODE key for
10 seconds

MODE key for
10 seconds



★ No key operation for about 2 minutes automatically moves the screen back to the operating mode screen.

★ If a function is not specified, corresponding SET screen is not displayed.

★ Holding the MODE key pressed for at least 2 seconds moves the setting item selection screen back to the

operating mode screen or vice versa.

★ Use the ▲/▼ key to move the parameter setting screens.

★ Use the MODE key to move each parameter setting screen.