■ Start SV permissible range setting

SEt14

tIME1

to

SEt16

tIME3

Setting content

Initial value

3

tSV1

to

tSV3

Thermocouple/resistance temperature detector input
0.0 to 999.9 (

C)

0 to 999 (

C)

0

Voltage/current input
0 to 9999 (digit)


When the SV start is set, it is set that at what temperature range (°C) the timer should start.

The permissible range is determined in the range of tSV with SV in the center as shown below.
When tSV is set to 1.0°C, the timer operates when the temperature falls within SV ± 0.5°C.

SV

tSV


Note When the ramp action is used together, tSV is set to target SV value.




■ ON delay timer/OFF delay timer/repeat count setting

SEt14

tIME1

to

SEt16

tIME3

Setting content

Initial value

4

oNt1

to

oNt3

0:00 to 99:59 (hour: minute or minute: second)

0:00

5

oFt1

to

oFt3

0:00 to 99:59 (hour: minute or minute: second)

0:00

6

RUN1

To

RUN3

0 to 99 counts (0 for unlimited counts)

1


Set the ON delay timer, OFF delay timer and repeat count setting of timers.

Use oNt 1 to 3 for setting the ON delay timer time of timers 1 to 3.
Use oFt 1 to 3 for setting the OFF delay timer time of timers 1 to 3.
Use RUN 1 to 3 for setting the repeat count of timers 1 to 3.

Note When the function setting of tMF 1 to 3 is set for the SV start, the ON delay timer screen is not displayed.


For the details on Timer Setting, please refer to Operation Manual Timer (P5 – 31 to 37).