4.2.10 Switchover to the ON/OFF control

The ON/OFF control is set in BANK 1 for the initial setting at factory shipment.
How to set the ON/OFF control is described.

Constant value run mode screen

PV value (present value)

SV value (target value)

Hold MODE key pressed for 2 seconds.

Input 1 setting screen

Each set screen

Each setting mode

Press the ▲ key three times.
Press it, however, twice for TTM-204.

Control setting mode

Press MODE key once.

S04-1 Bank setting mode

H

o

ld

MOD

E

k

ey

p

re

ss

ed

fo

r

2

se

co

n

d

s.

* Setting change to the ON/OFF control is conducted in the bank setting screen.
Changing “0” to “1” using the ▲ key results in the setting of the ON/OFF control.
Then, holding the MODE key pressed for 2 seconds, the screen moves back to the operating mode screen.
(In about 2 minutes, the screen automatically moves back to the operating mode screen.)
* The sensitivity range for the ON/OFF control is set at 1 °C at factory shipment.
* Setting the ON/OFF control results in displaying no items related to the PID control.

For program run mode screen:

PV value (present value)

SV value (PRoG)

Hold MODE key pressed for 2 seconds

Setting mode is the same as that for constant
value run mode.