7.5.3 Input 2 setting mode (SET 02)

Setting data

Character

Setting (monitor) value

Initial value

Unit

Setting

value

Blind

Input type

INP2

16: 0 - 1 VDC
17: 0 - 5 VDC
18: 1 - 5 VDC
19: 0 - 10 VDC
20: 4 - 20 mADC

18

None

Scaling upper limit

FSH2

FSL 2 to SV setting range upper
limit

1200

Scaling lower limit

FSL2

SV setting range lower limit to
FSH 2

0

PV compensation
gain

PVG2

0.500 to 2.000

1.000

Times

PV compensation
zero

PVS2

-999 to 999

0

Digit

PV filter

PdF2

0.0 to 99.9

0.0

Second

Local/remote
switchover

LR

0: Local
1: Remote 1

(Scaled with SLL , SLH )

2: Remote 2

(Scaled with FSL 2, FSH 2)

0

None


7.5.4 Key function setting mode (SET 03)

Setting data

Character

Setting (monitor) value

Initial value

Unit

Setting

value

Blind

Function key 1
function
Function key 2
function
Function key 3
function
Function key 4
function
Function key 5
function

FU1

to

FU5

*0: No function
*1: Digit shift
*2: Control mode (MD)/control

stop (RDY)

*3: AT start/AT stop
*4: Timer start/stop
*5: Screen reverse feed
*6: ENT
*7: Bank switchover
*8: AUTO/MANUAL
*9: SV/MV screen switchover
*A: Constant value run mode/

Program mode switchover *1

*B: Step feed *1
*C: Pause *1
*d: SET 22 call-up function *1

0.0

None

0*: None
1*: Pressing time of 1 second
2*: Pressing time of 2 seconds
3*: Pressing time of 3 seconds
4*: Pressing time of 4 seconds
5*: Pressing time of 5 seconds

Second

Key lock

LoC

0: Lock OFF
1: Lock all
2: Lock of run mode
3: Lock of other than run mode
4: Lock all (only during a run) *1
5: Lock of run mode (only during

a run) *1

6: Lock of other than run mode

(only during a run) *1

7: Lock of parameter mode (only

during a run) *1

0

None


*1: Selectable only on Ver3.xx or later