6 basic flow of setting, Basic flow of setting -11 – TOHO ELECTRONICS TTM200 User Manual

Page 17

Advertising
background image

48-7009-E

1-11

1.6 Basic flow of setting


Power-on

The mode changes to either

“constant value run mode” or “program run mode” when four seconds are

elapsed after the power is turned-on

.

Initial screen

4 sec

* Constant run value mode is established with the SET 21 operating type setting (C/P

0).

In addition, the SET 21 and 22 parameters are not displayed.
* With SET 23 bAF

1, the auto bank switchover function is selectable.

With bAF

0, the SET 23 parameters are not displayed.

Constant value run mode

* All setting item selection screens can move to the

constant value run mode screen.

MODE key for 2 seconds

The screen SET 01 appears when the run mode
screen moves to each setting item selection screen.

Each setting item selection screen

SET 01 - SET 23

* Using the ▲/▼ key, the setting item selection

screens SET 01 to SET 23 are displayed in
sequence.

(In case of no function registered, the

corresponding screen is not displayed.)

(For bank auto-switchover, see page 6-15.)

Blind setting

screen

Parameter setting

screen in each

SET

* Each parameter setting

screen is displayed in
sequence when the MODE
key is pressed on the
parameter setting screen,
which is displayed when the
MODE key is pressed in each
setting item selection screen
(SET**). Holding the MODE
key pressed for at least 2
seconds moves each
parameter setting screen back
to the run mode screen.

Program run mode

* Program run mode is established

with the SET 21 operating type
setting (C/P

0).

* With SET 23 bAF

1,

the auto bank
switchover function
is selectable.

With bAF

0, the

SET 23 parameters
are not displayed.

MODE key for 2 seconds

Each setting item selection

screen SET 01 - SET 23

* Using the ▲/▼ key, the setting item selection

screens SET 01 to SET 23 open in sequence.

(In case of no function registered, the

corresponding screen is not displayed.)

(For program run, see page 6-13.)
(For bank auto-switchover, see page 6-15.)

Blind setting

screen

Parameter setting

screen in each

SET

* All setting item selection screens can move

to the run mode screen.

* Each parameter setting screen

is displayed in sequence when
the MODE key is pressed on the
parameter setting screen, which
is displayed when the MODE
key is pressed in each setting
item selection screen (SET**).
Holding the MODE key pressed
for at least 2 seconds moves
each parameter setting screen
back to the run mode screen.

* A shortcut to SET 22 can be

made if FU*

d is set for the

SET 3 function key function
setting.

(For details, see pages 6-12 and

13.)

* The screen moves back to the run mode screen in case of no key operation in each setting item

selection screen or parameter setting screen in each SET for about 2 minutes.

* For how to set the blind setting, see pages 4-27 and 28, the section 4-2-

9 “Basic operation.”