7-8

(5) Power consumption

100 - 240 VAC: 10 VA or less (TTM-204)
100 - 240 VAC: 11 VA or less (other than TTM-204)
24 VAC/DC: 4 W or less (TTM-204)

(6) Warm-up time

30 minutes

(7) Momentary power outage

No effect of power outage in a single cycle.
(Reset at power outage for more than a cycle)
For DC power with the outage for 40 ms or shorter, there is no effect on
operation.

(8) Isolation resistance

Measurement terminal - case

00 VDC, 20 M

Power terminal - case

500 VDC, 20 M

(9) Withstand voltage

Measurement terminal - case

1000 VAC for a minute

Power terminal - case

1500 VAC for a minute

(10) Weight

TTM-204: 120 g or less
TTM-205: 210 g or less
TTM-207: 260 g or less
TTM-209: 300 g or less

(11) Protection structure

IP66 or equivalent (on the front surface): Only for TTM-204
For TTM-205, 207 and 209, no IP regulation applicable.
(Due to installation for loader communication)