TOHO ELECTRONICS TTM200 User Manual

Page 227

Advertising
background image

48-7009-E

6-79

Repeat Start Step Setting / Repeat End Step Setting / Setting the Times of Execution / Setting the no. of

Execusion / No. of Times Monitor

SEt22

PROG

Setting Contents

Initial

Value

5

StRSt

Repeat Start Step Setting 3

1

Setting Value Range

1~Repeat End Step Setting

(ENdSt)

6

ENdSt

Repeat End Step Setting 3

StEPN

Repeat Start Step Setting (StRSt StRSt)~

Setting No. of Steps to be used or StEPN

When set to StEPN, the value which is set under the
Setting No. of Steps to be Used will be “Repeat End Step
Setting”.

7

RUNP

No. of Execution Setting / No. of Execution Monitor 3

1

Setting Value Range

RUNP=0~9999

When RUNP=0, Infinite)

Setting the condition of repeated operation during the programmed operation

5 Repeated Start Step Setting (StRSt)

This is to set the starting point of the repetition (Step No. of which the repetition starts)

6 Repeated End Step Setting (ENdSt)

This is to set the end point of the repetition (Step No. of which the repetition ends)

7 Setting No. of Executions / No. of Executions Monitor (RUNP)

This is to set the no. of time of repetition at the start point and end point.

NOTE: The setting value of the “No. of Executions Setting ” and “No. of Executions” done will be shown alternately only
on the display of the controller unit.

Repeat Operation Behavior Diagram

STEP1

STEP2

STEP3

STEP2

STEP3

STEP2

STEP3

STEP4

programmed

operation

start

Repeated Start Step Setting : STEP2
Repeated End Step Setting : STEP3
Setting No. of Executions  : 3 times

programmed

operation

end

Above is usage example of Repeat Operation Function




Advertising