5 output (from out 1 to out 7) type setting, Output (from out 1 to out 7) type setting -49 – TOHO ELECTRONICS TTM200 User Manual

Page 197

Advertising
background image

48-7009-E

6-49

6.5 Output (from OUT 1 to OUT 7) type setting

■ Outputs 1 to 7 target connection setting

SEt05

oUt1

to

SEt11

oUt7

Setting content

Initial value

1

o1F

to

o7F

0

Primary output

1

Secondary output

2

Event output

3

RUN output

4

RDY output

5

Timer 1 output

6

Timer 1 during-on-delay output

o1F: 0

7

Timer 1 during-off-delay output

8

Timer 1 during-[on + off]-delay output

9

Timer 2 output

o2F: 2

10

Timer 2 during-on-delay output

to

11

Timer 2 during-off-delay output

o7F: 2

12

Timer 2 during-[on + off]-delay output

13

Timer 3 output

14

Timer 3 during-on-delay output

15

Timer 3 during-off-delay output

16

Timer 3 during-[on + off]-delay output

17

Transmission output (for analog output)

18

End Output (during program mode)

3

Set target connections for outputs 1 to 7.
This product allows free setting of output applications.
This product also allows duplicated setting of outputs 1 and 2 (such as setting the both outputs for either primary or secondary
output).

Note Transmission output can be selected only when the output 1 or 2 at order placement for the product is of analog output.

As no analog output being available for outputs 3 to 7, they cannot be set for the transmission output.

For operation of the event function 1 of the event output, see section of event function 1 operation on page 6-49.

For operations of the event functions 2 to 4 of the event output, see section of event functions 2 to 4 operations on pages 6-50
to 52.

For operation of the timer output, see section “5.4.5 Timer function” on pages 5-32 to 37.