2 transmitter in field housing, 1 overview of the instrument, Communication protocols – Rice Lake PR5230 Fieldbus Transmitter User Manual

Page 12: Transmitter in field housing, Overview of the instrument, 2transmitter in field housing, Pr 5230 instrument manual

Advertising
background image

Transmitter in Field Housing

PR 5230 Instrument Manual

EN-12

Sartorius

2

Transmitter in Field Housing

The instrument is equipped with a 128 x 64 pixel display for weight values with max. 6 digits and additional
status indication.

2.1

Overview of the Instrument

-

Accuracy 10,000 e (Class III) for the weighing electronics

-

High-speed conversion with response times from 5 msec

-

Weight indication with status by monochrome 128 x 64 pixel display

-

3 function keys in the housing, function configurable

-

Wall-mounted stainless steel housing, with IP 66 protection

-

LAN adaptor with 10/100 Mbit/sec for data transfer, calibration, parameterization

-

RS-232 interface, built-in; for connecting e.g. a printer or a remote indicator

-

RS-485 interface, built-in; for connecting e.g. PC

-

Expansion possible by addition of following plug-in circuit boards (3 slots):

- Analog output board PR 5230/06
- Load cell junction board PR 5230/22
- Interfaces PR 1721/4x

-

3 opto-decoupled outputs (optional)

-

3 configurable relay outputs with change-over contact

-

3 configurable optocoupler inputs, potential-free internal supply possible (optional)

-

Galvanically isolated interfaces (except RS-232)

-

Wide range power supply for 100 to 240 V AC, protection class I (protective earth)

-

Version PR 5230 for 24 V direct current

-

Version PR 5230 with intrinsically safe load cell supply (optional)

-

Plug-in connections inside the instrument for load cells, inputs/outputs, LAN adaptor, serial interfaces

-

Calibration using PC tool (Browser/VNC)

-

Calibration using weights, by entering mV/V values, or directly, using load cell data ("smart calibration")

-

Software configuration of the interface cards, e.g. for remote display or printer

-

Analog test for the weighing electronics

Communication Protocols
For the internal RS-232 or RS-485:

Fieldbus Slave (accessories):

-

Remote display protocol

-

PR 1721/41

ProfiBus-DP

-

Printer

-

PR 1721/42

InterBus-S

-

J-Bus/ModBus (Slave)

-

PR 1721/44

DeviceNet

-

SMA protocol

-

PR 1721/45

CC-Link

-

xBPI protocol

-

PR 1721/46

ProfiNet I/O

-

Asycom protocol

-

PR 1721/47

EtherNet-IP

For the internal LAN:

-

ModBus-TCP

-

Ethernet-TCP/IP

-

OPC