1 status indication – Rice Lake PR5230 Fieldbus Transmitter User Manual

Page 15

Advertising
background image

PR 5230 Instrument Manual

Transmitter in Field Housing

Sartorius

EN-15

2.3.1.1

Status Indication

For status indication, max. 5 lines can be configured by selecting from a menu (see Chapter 5.6.7).

Selection

Width

Height

Example

Description

Empty

½ Display

1 Line

Empty line

Gross/Net/Tare

½ Display

1 Line

B

+123.45kg

Gross/Net/Tare

B

E:Sense

Error, see Chapter 15.1

Gross

½ Display

1 Line

B

+123.45kg

Gross

Net

½ Display

1 Line

NET

+123.45kg

Net

Tare

½ Display

1 Line

T

+123.45kg

Tare

Bargraph

1 Display

1 Line

Shows the weight in
proportion to nominal
capacity.

Fieldbus LEDs

½ Display

1 Line

––– red ––– grn

See Chapter 4.4.

Fieldbus Inputs

1 Display

1 Line

FB-Inp: 01.23.45.67.89.AB.CD.EF Fieldbus Inputs

Fieldbus Outputs

1 Display

1 Line

FB-Out: 01.23.45.67.89.AB.CD.EF Fieldbus Outputs

Digital inputs

½ Display

1 Line

Inputs:



Digital inputs: 1, 2, 3

Digital outputs

½ Display

1 Line

Outputs:



Digital outputs: 1, 2, 3

Digital I/O

½ Display

1 Line

I: O:

Digital in-/outputs: 1, 2, 3

Analog output

½ Display

1 Line

Ana:

12.345mA

Analog output

Limits

½ Display

1 Line

Limits:



Limits: 1, 2, 3

Date

½ Display

1 Line

2009-12-31

Date

Time

½ Display

1 Line

10:37:34

Time

Hostname

½ Display

1 Line

HOPPER1

Device name in the network

Hostname (long)

1 Display

1 Line

Small Material Hopper Device name (long)

IP-Address

½ Display

1 Line

192.168.1.1

Network address

---.---.---.---

No network

??.??.??.??

Search DHCP server

IP-Address (long)

1 Display

1 Line

172.200.280.255

Network address (long)

Gross (2 lines high)

1 Display

2 Lines

B

+123.45 kg

Gross (2 lines high)

Net (2 lines high)

1 Display

2 Lines

NET

+123.45 kg

Net (2 lines high)

Tare (2 lines high)

1 Display

2 Lines

T

+123.45 kg

Tare (2 lines high)

Advertising