3 pr 5230/22 load cell junction board, Pr 5230/22 load cell junction board, Installing the instrument and plug-in cards – Rice Lake PR5230 Fieldbus Transmitter User Manual

Page 72: Pr 5230 instrument manual

Advertising
background image

Installing the Instrument and Plug-in Cards

PR 5230 Instrument Manual

EN-72

Sartorius

4.4.3

PR 5230/22 Load Cell Junction Board

The load cell junction board is connected to the main board by a flat cables plug.

Number of load cells

1…4

Type of load cells

Strain gauge, 6 or 4-wire
connection possible

Internal connection

14-pin flat plug 

External connection

4x 4-pin terminal block 

Load cell cable length

500 m max.

Dimensions (LxWxH)

95 x 74 x 19 mm

Weight

33 g

Advertising