Cc-link, Profinet i/o, Ethernet/ip – Rice Lake PR5230 Fieldbus Transmitter User Manual
Page 147: Closing the menu, Pr 5230 instrument manual commissioning
Advertising
PR 5230 Instrument Manual
Commissioning
Sartorius
EN-147
[CC-Link]
Setup/
Fieldbus parameter
Fieldbus protocol
CC-Link
CC-Link baudrate
156k Select 156k, 625k, 2.5M, 5M or 10M
CC-Link ID
1 Enter address
[ProfiNet I/O]
Setup/
Fieldbus parameter
Fieldbus protocol
ProfiNet I/O
Use DHCP
off Select on/off
IP address
192.168.1.1 Enter IP address
Subnet mask
255.255.255.0 Enter Subnet mask
[EtherNet/IP]
Setup/
Fieldbus parameter
Fieldbus protocol
Ethernet/IP
Use DHCP
off Select on/off
IP address
192.168.1.1 Enter IP address
Subnet mask
255.255.255.0 Enter Subnet mask
Closing the menu
To close the menu, press
. The following message is displayed:
Press [Yes] to save the data.
Press [No] to close the menu without changing data.