PR 5230 Instrument Manual

SMA Protocol

Sartorius

EN-177

7.3

SMA Command Set

The SMA command set is intended for requesting weight values and status information as well as for control
of the scale. The commands start with <LF> and end with <CR>.
Format: <LF>c<CR>

Requesting a Weight

Requesting a Weight

Command: <LF>W<CR>
Reply:

The scale immediately returns the weight and status: gross weight if not tared, net weight if
tared.

<LF><s><r><n><m><f><xxxxxx.xxx><uuu><CR>

For details, see page 180.

Requesting the Weight with Stability

Command: <LF>P<CR>
Reply:

The scale returns the weight and the status only, when the stability condition is met: Gross
weight if not tared, net weight if tared.

For this function, the stability condition must be met. The maximum waiting time for stability is
set under [Tare timeout]; see Chapter 5.4.13.

<LF><s><r><n><m><f><xxxxxx.xxx><uuu><CR>

After elapse of the waiting time without reaching stability, the following reply is sent:

<LF><_><1><n><_><f><----------><___><CR>

For details, see page 180.

Requesting Weight Continuously
This is a command which generates non-requested replies, because it does not function according to the strict
pattern of command and reply. After the command, the scale repeats the reply continuously.

Command: <LF>R<CR>
Reply:

The scale repeats the weight and status information continuously until another command is
received.

<LF><s><r><n><m><f><xxxxxx.xxx><uuu><CR>

For details, see page 180.

Dependent on the used baud rate, the repetition rate of reply telegrams is roughly as follows:
19200 Bd

100 ms

9600 Bd

110 ms

4800 Bd

170 ms

Requesting the High-Resolution Weight

Command: <LF>H<CR>
Reply:

The scale immediately returns the high-resolution (10x) weight and status: Gross weight if not
tared, net weight if tared.

Note: The <n> gross/net status is shown in lower-case letters while the high-resolution weight is
sent.

<LF><s><r><n><m><f><xxxxxx.xxx><uuu><CR>

For details, see page 180.

Advertising