2 pr 5230/06 analog output board, Pr 5230/06 analog output board – Rice Lake PR5230 Fieldbus Transmitter User Manual

Page 71

Advertising
background image

PR 5230 Instrument Manual

Installing the Instrument and Plug-in Cards

Sartorius

EN-71

4.4.2

PR 5230/06 Analog Output Board

The analog output board is a plug-in card for installation in Slot 1. It has a 2-pole screw terminal for an active
analog output.

Internal connection

20-pin flat plug

Number of channels

1 active current output: 20 mA,
10 V output voltage via external 500 ¥ resistor

Output function

Gross/Net/display tracking, configurable

Output range

0/4…20 mA, configurable

Resolution

16 bit binary,
20.000 internal digits @ 20 mA

Linearity error

@ 0 – 20 mA: 0.04 %
@ 4 – 20 mA: 0.02 %

Temperature effect

<100 ppm/K

Zero error

0.05 %

Max. error

<0.1 %

Load

0…500 ¥ max.

Potential isolation

yes

Protected against short

circuits

yes

External connection

2- pin plug-in terminal block

Accessories

Mounting screws M3 x 12 mm,
spacer ring 2 mm thick

Dimensions (LxWxH)

85 x 22 x 14 mm

Weight

15 g


Current Output

Voltage Output

Current is supplied directly via the terminals.

The voltage corresponds to the drop across the
external 500 ¥ resistor.