Fieldbus Interface
PR 5230 Instrument Manual
EN-198
Sartorius
Register 5: Device Type and Software Release
Only reading is permitted.
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Byte 0
TYPE MSB
Byte 1
TYPE LSB
Byte 2
MAINVERSION
Byte 3
SUBVERSION
e.g. 5230 Rel. 1.00 = 52300100
hex
Register 6: Board Number
Only reading is permitted.
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Byte 0
Board number MSB
Byte 1
""
Byte 2
""
Byte 3
Board number LSB
e. g. 148388723 = 08D83B73
hex
Register 7: (Reserved)
Register 8 ...15: Weight Data
Only reading is permitted.
The gross, net and tare weight are stored as DINT fix point.
The real data value is derived from DINT and EXPO as follows:
Value
Real
=reading
DINT
*10
(-EXPO
Register 8
Current gross value
Register 9
Current net value, if tared; otherwise gross
Register10
Current tare value, if tared, otherwise 0
Register11
Actual gross/net selected with X72
Register12
Reserved
Register13
Reserved
Register14
Max
Register15
Reserved