Register 5: device type and software release, Register 6: board number, Register 7: (reserved) – Rice Lake PR5230 Fieldbus Transmitter User Manual

Page 198: Register 8 : weight data, Fieldbus interface, Pr 5230 instrument manual

Advertising
background image

Fieldbus Interface

PR 5230 Instrument Manual

EN-198

Sartorius

Register 5: Device Type and Software Release
Only reading is permitted.

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Byte 0

TYPE MSB

Byte 1

TYPE LSB

Byte 2

MAINVERSION

Byte 3

SUBVERSION

e.g. 5230 Rel. 1.00 = 52300100

hex

Register 6: Board Number
Only reading is permitted.

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Byte 0

Board number MSB

Byte 1

""

Byte 2

""

Byte 3

Board number LSB

e. g. 148388723 = 08D83B73

hex

Register 7: (Reserved)

Register 8 ...15: Weight Data
Only reading is permitted.
The gross, net and tare weight are stored as DINT fix point.
The real data value is derived from DINT and EXPO as follows:

Value

Real

=reading

DINT

*10

(-EXPO

Register 8

Current gross value

Register 9

Current net value, if tared; otherwise gross

Register10

Current tare value, if tared, otherwise 0

Register11

Actual gross/net selected with X72

Register12

Reserved

Register13

Reserved

Register14

Max

Register15

Reserved