Analog output, Er 5.10, Commissioning – Rice Lake PR5230 Fieldbus Transmitter User Manual

Page 158: Pr 5230 instrument manual, 10 analog output

Advertising
background image

Commissioning

PR 5230 Instrument Manual

EN-158

Sartorius

5.10

Analog Output

The analog output card PR 5230/06 can be mounted in slot 1.

Define the analog output parameters under

-[Analog output

parameter

].

Press

to select the specific parameter.

Press

to select the respective values.

Setup/

Analog output parameter

Analog mode

Gross

D08

Analog range

0…20 mA

Output on error

0 mA

Output if < 0

linear

Output if > Max

linear

Weight at 0/4 mA

0 g

Weight at 20 mA

240000 g

[Analog mode]

[no output]

The analog output is not used

[Gross

D08]

Output of the gross weight

[Net if tared D09]

Output of the net weight, if tared; otherwise gross weight

[Selected

D11]

Output Gross or Net, depending on SPM-Bit X72

[Transparent D30]

Output of the value in D30

[Analog range]

[0...20 mA]

Output of 0... 20 mA

[4...20 mA]

Output of 4... 20 mA

[Output on error]

[0 mA]

Set the output to 0 mA

[4 mA]

Set the output to 4 mA

[20 mA]

Set the output to 20 mA

[Output if < 0]

[0 mA]

Set the output to 0 mA

[4 mA]

Set the output to 4 mA

[20 mA]

Set the output to 20 mA

[linear]

The output drops below 4 mA up to the limitation
(at 4 .. 20 mA)

[Output if > Max] [0 mA]

Set the output to 0 mA

[4 mA]

Set the output to 4 mA

[20 mA]

Set the output to 20 mA

[linear]

The output exceeds 20 mA up to the limitation

[Weight at 0/4 mA]

Weight value for 0/4 mA output

[Weight at 20 mA]

Weight value for 20 mA output

Press

to return to the previous menu.


Advertising