Relay Outputs

The main board has 3 digital outputs for process control, electrically isolated by optocouplers, each bipolar
potential-free.

Number of outputs 3 (CH 1, CH 2, CH 3)
Output

Change-over contact
Max. switching voltage
Max. switching current


250 V AC
5.0 A


250 V DC
0.3 A

Electrical isolation Free relay change-over contact
Connection

Plug-in terminal block,
each with 3 pins,
conductor cross-section max. 1.5 mm

2


Component layout on the main board
In this option the jumper R320 …R325 are fitted on the main board.

R321

R323

R325

R324

R322

R320

4.2.8.1

Connecting Example: Relay control

The relay switches, when the output
is active (true). For protection of the
output circuit, relays with free-wheel
diode must be provided.

4.2.8.2

Connecting Example: Voltage output

When the output is active (true), the
output voltage goes from
24 V/12 V to 0 V.
The load resistance must be
2.2 k¥/1 k¥.