Installing the Instrument and Plug-in Cards
PR 5230 Instrument Manual
EN-62
Sartorius
The 4 load cell cores are color-marked:
Terminal block
Color
Connection
Description
-
V
blue (bu)
-
Supply
-
Supply
+ V
red (rd)
+ Supply
+ Supply
-
M
grey (gy)
-
Meas./LC out
-
Measuring voltage/load cell output
+ M
green (gn)
+ Meas./LC out
+ Measuring voltage/load cell output
Caution!
The cable colors shown above are applicable to the 4-wire PR 62.. series load cells.
Before connecting, check the assignment of cable colors in the load cell manual.
Note:
The load cells are connected directly. Corner adjustment on the load cell junction board is not
provided.