4.4.4

PR 1721/41 ProfiBus-DP Interface

The ProfiBus interface PR 1721/41 is a plug-in card for mounting in slot 2; see Chapter 4.4.1. Communication
protocols and syntax comply with the ProfiBus-DP standard to IEC 61158, with transfer rates up to 12 Mbit/s.

Internal connection 34- pin connector on flat cable for

slot 2

External connection 6-pin plug-in terminal block

VP DGND A B free free

A = cable color: green
B = cable color: red
Transfer rate

9.6 kbit/s to 12 Mbit/s,
baud rate auto-detection

Connection mode

ProfiBus network,
connections can be made/released
without affecting other stations

Protocol

PROFIBUS-DP-V0 slave
to EN 50 170 (DIN 19245),
mono or multi-master systems are
supported. Master and slave devices,
max. 126 nodes possible.
Watchdog timer

Addressing

Via software, rotary switch on
position 0

Configuration

GSD file
‚Sart5230.gsd’

Bus termination

Via DIL-switch

Cable

Special ProfiBus
color: violet, shielded
twisted pair cable

Certificates

ProfiBus test center Comdec in Germany
and PNO (ProfiBus User Organization).
Suitable for industrial applications to
CE, UL and cUL

Cable impedance

150 ¥

Dimensions (LxWxH) 87 x 55 x 15 mm

Potential isolation Optocoupler in lines A and B (RS-485)

Weight

35 g

Cable length

Max. distance 200 m can be extended
with 1.5 Mbit/s by means of additional
repeater.


Note:

The GSD file is stored on the CD (directory ‘Fieldbus’ of the according instrument) supplied with
the unit. The current file is also available for download via the Internet:
http://www.sartorius-mechatronics.com [Downloads].