Tare timeout, Zeroset range, Zerotrack range – Rice Lake PR5230 Fieldbus Transmitter User Manual

Page 123: Zerotrack step, Zerotrack time, Overload, Minimum weight, Range mode, Er 5.4.13.1, Pr 5230 instrument manual commissioning

Advertising
background image

PR 5230 Instrument Manual

Commissioning

Sartorius

EN-123

Weighingpoint/WP A/

Calibration

Tare timeout

2.5 s

Zeroset range

50.00 d

Zerotrack range

0.25 d

Zerotrack step

0.25 d

Zerotrack time

0.0 s

Overload

9 d

[Tare timeout]
Enter a timeout value between 0.1 and 25 s for a taring/zero set command that cannot be executed (e.g., if
scale mechanically unstable, filter settings faulty, resolution too high, stability condition too narrow).

[Zeroset range]
Determine a ±range around the zero point determined by the dead load during calibration; within this range
-

the displayed gross weight can be set to zero by pressing the zero-setting key (or by a corresponding

external command), and

-

automatic zero tracking is active.

Available range: 0.00…10000.00d
In 'legal-for-trade' mode a value

≤2 % of max. must be entered. Example: 60 d for 3000e, class III.

[Zerotrack range]
Range within which automatic zero tracking compensates deviations, 0.25…10000.00d.
In 'legal-for-trade' mode a value of 0.25 d has to be entered.

[Zerotrack step]
If a weight change exceeds the adjusted value, automatic tracking does not function any more. Step for
automatic tracking 0.25…10d. In 'legal-for-trade' mode a value of 0.25 d has to be entered.

[Zerotrack time]
Enter a time interval for automatic zero tracking within. At 0.0 s the tracking is switched off.
In 'legal-for-trade' mode a value of 1 s has to be entered.

[Overload]
Weighing range above the maximum capacity [Max], without error message. Available range: 0…999900 d.
In 'legal-for-trade' mode max. 9 d = e has to be entered.

Weighingpoint/WP A/

Calibration

Minimum weight

50 d

Range mode

Single range

[Minimum weight]
Weighing range above the maximum capacity (Max), without error message. Available range: 0…999900 d.
In 'legal-for-trade' mode min. 20 d has to be entered.

[Range mode]
For scale range selection, see Chapter 5.4.13.2.

Advertising