3 connecting load cells, 1 connecting a load cell with 4-wire cable, 2 connecting pr 6221 load cells – Rice Lake PR5230 Fieldbus Transmitter User Manual

Page 60: Connecting load cells, Connecting a load cell with 4-wire cable, Connecting pr 6221 load cells, Installing the instrument and plug-in cards, Pr 5230 instrument manual

Advertising
background image

Installing the Instrument and Plug-in Cards

PR 5230 Instrument Manual

EN-60

Sartorius

4.3

Connecting Load Cells

Load cells or analog platforms (e.g. from the CAPP series) can be connected.
The supply voltage is protected from short circuit and overload.

Caution!
Do not shorten the load cell cable. Connect the prepared cable end and roll up the

remaining cable.

Terminal block Connection Description
+ M

+ Meas.

+ Meas. voltage/load cell output

-

M

-

Meas.

-

Meas. voltage/load cell output

+ V

+ Supply + Supply voltage

+ S

+ Sense

+ Sense

-

S

-

Sense

-

Sense

-

V

-

Supply -

Supply voltage

Ground

Ground

4.3.1

Connecting a Load Cell with 4-Wire Cable

Caution!
The cable colors shown above are applicable to the 4-wire PR 62.. series load cells.
Before connecting, check the assignment of cable colors in the load cell manual.







Provide links:
between – Supply (-V) and – Sense (-S)
between + Supply (+V) and + Sense (+S)

4.3.2

Connecting PR 6221 Load Cells

See installation manuals of PR 6221 and PR 6021/08, -/68.

Advertising